4.8/5
Rated 5 out of 5

20Kva 3 Phase SDEC

20 Kva 3 Phase Diesel Silent Generator with automatic transfer switch (ATS) with SmarGen Controller

Product Description

DIESEL GENERATOR Powered by SDEC Engine & copy Stamford Alternator Standard Specifications three phase, output voltage 380V,50HZ, power factor:0.8(lagging), protection grade is accordance with NAME 1 and IP23. General Features: ● Coupled with SDEC diesel engine and copy Stamford alternator ● Air filter, fuel filter, oil filter ● Lube-oil drain valve fitted ● Water-cooled ● 8 hrs operation base fuel tank ● Soundproof ● MCB CHINT breaker ● Operation & Maintenance manual ● Steel-fabricated base frame with power coating ● Battery free maintance Generating Set Data Voltage regulation,steady state:≤±1% Sudden voltage warp (100% sudden reduce):≤±25% Sudden voltage warp (Sudden increase): ≤-20% Voltage stable time (100% sudden reduce): ≤6S Voltage stable time (Sudden increase): ≤6S Frequency regulation,steady state: ≤5% Frequency Waving: ≤1.5% Sudden frequency warp: (100% sudden reduce): ≤+12% Sudden frequency warp: (Sudden increase):≤-10% Frequency recovery time (100% sudden reduce): ≤5S Frequency recovery time (sudden increase): ≤5S Generator Ratings: Voltage Hz Phase P.F.Cos Standby Amps Standby Ratings (kW/kva) Prime Ratings (kW/kva) 380 50 3 0.8 42 22/27.5 20/16 Prime power (RPR) is the normal output continuously available, where the average load (variable) does not exceed 70% of the prime power rating during an operating period of 250 hours. The total operating time at 100% prime power must not exceed 500 hours per year.A 10% overload is available for a maximum of 1 hour in 12 hours of operation and must not exceed a total of 25 hours per year. Standby Power (LTP) is the maximum output available (at variable load), for up to 200 hours per year. The average load (variable) must not exceed 80% of the standby power rating, with less than 25 hours per year at the full standby rating. No overload is available. The genset must not operate, at standby rating, in parallel with the public utility under any circumstances. Engine Technical Data General Units 50HZ Emission certifficates / Rated speed rpm 1500 Engine Basic Data Engine Brand – Model RICARDO ZH4100D Engine Max.output kW 33 Number of cylinders 4 Cylinder arrangement Inline Type of air intake Natural Aspirated Type of cooling Water-cooled Bore*Stroke mm 100*115 Speed control Mechanical Speed drop ±5% Fuel system Full load Fuel consumption rate G/KW.H ≤251 Fuel tank capacity L 80 Oil system Oil consumption rate G/KW.H ≤2.04 Oil sump capacity L 13 Electrical system Voltage of electric system V 12 Type of battery Lead acid type Alternator Technical Data Model 184E Brand DE Prime Power (kW) 16kW Excitation Type Brushless self-excitation Voltage Regulator Type Automatic Voltage Regulator AVR Model SX460 Power Factor (Cos) 1 Altitude ≤1000m Overspeed 2250RPM Number of Pole 4 Winding Leads 12 Insulation class H Drip proof IP23 Voltage regulation ±1% Total harmonics (TGH/THC) at no load < 1.5% – on load < 2% Wave form: NEMA=TIF <50 Wave form: I.E.C = THF <2% Bearing Single Coupling Direct Dimension & Weight Open Type (Standard Configuration) Overall Size: 2050*850*1150 mm(L*W*H) Weight:1000Kgs Soundproof Type Overall Size: 2300*930*1250 mm(L*W*H) Weight: 930Kgs